1.
J Clin Med ; 13(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38592263

RESUMO

Uremic toxins (UTs), particularly protein-bound uremic toxins (PBUTs), accumulate in chronic kidney disease (CKD) patients, causing significant health complications like uremic syndrome, cardiovascular disease, and immune dysfunction. The binding of PBUTs to plasma proteins such as albumin presents a formidable challenge for clearance, as conventional dialysis is often insufficient. With advancements in the classification and understanding of UTs, spearheaded by the European Uremic Toxins (EUTox) working group, over 120 molecules have been identified, prompting the development of alternative therapeutic strategies. Innovations such as online hemodiafiltration aim to enhance the removal process, while novel adsorptive therapies offer a means to address the high affinity of PBUTs to plasma proteins. Furthermore, the exploration of molecular displacers, designed to increase the free fraction of PBUTs, represents a cutting-edge approach to facilitate their dialytic clearance. Despite these advancements, the clinical application of displacers requires more research to confirm their efficacy and safety. The pursuit of such innovative treatments is crucial for improving the management of uremic toxicity and the overall prognosis of CKD patients, emphasizing the need for ongoing research and clinical trials.

2.
Clin Kidney J ; 16(4): 735-744, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37007697

RESUMO

Background: Kt/Vurea is the most used marker to estimate dialysis adequacy; however, it does not reflect the removal of many other uraemic toxins, and a new approach is needed. We have assessed the feasibility of estimating intradialytic serum time-averaged concentration (TAC) of various uraemic toxins from their spent dialysate concentrations that can be estimated non-invasively online with optical methods. Methods: Serum and spent dialysate levels and total removed solute (TRS) of urea, uric acid (UA), indoxyl sulphate (IS) and ß2-microglobulin (ß2M) were evaluated with laboratory methods during 312 haemodialysis sessions in 78 patients with four different dialysis treatment settings. TAC was calculated from serum concentrations and evaluated from TRS and logarithmic mean concentrations of spent dialysate (MlnD). Results: Mean (± standard deviation) intradialytic serum TAC values of urea, UA, ß2M and IS were 10.4 ± 3.8 mmol/L, 191.6 ± 48.1 µmol/L, 13.3 ± 4.3 mg/L and 82.9 ± 43.3 µmol/L, respectively. These serum TAC values were similar and highly correlated with those estimated from TRS [10.5 ± 3.6 mmol/L (R 2 = 0.92), 191.5 ± 42.8 µmol/L (R 2 = 0.79), 13.0 ± 3.2 mg/L (R 2 = 0.59) and 82.7 ± 40.0 µmol/L (R 2 = 0.85)] and from MlnD [10.7 ± 3.7 mmol/L (R 2 = 0.92), 191.6 ± 43.8 µmol/L (R 2 = 0.80), 12.9 ± 3.2 mg/L (R 2 = 0.63) and 82.2 ± 38.6 µmol/L (R 2 = 0.84)], respectively. Conclusions: Intradialytic serum TAC of different uraemic toxins can be estimated non-invasively from their concentration in spent dialysate. This sets the stage for TAC estimation from online optical monitoring of spent dialysate concentrations of diverse solutes and for further optimization of estimation models for each uraemic toxin.

3.
Clin Kidney J ; 15(6): 1196-1201, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35664275

RESUMO

Hyponatremia is acute when present for <48 h. Most cases of acute hyponatremia involve both excess free water intake and an at least partial urinary free water excretion defect. By contrast, hyperacute water intoxication may result from a large excess electrolyte-free water intake in such a short time that properly working urinary free water excretion mechanisms cannot cope. A hyperacute decrease in serum sodium may lead to death before medical intervention takes place. Well-documented cases have been published in the military medicine literature. In addition, news reports suggest the existence of cases of voluntary ingestion of excess free water by non-psychiatric individuals usually during 'dare' activities. Education of the public is required to prevent harm from these high-risk activities. Adequate training of emergency medical units may prevent lethal outcomes. Spanish media reported the case of a male who died following his triumph in a 20-min beer drinking contest. 'From a heart attack. Man dies after drinking six litres of beer in a contest' ran the news. We now review the physiology underlying hyperacute water intoxication and discuss the potential contribution of hyperacute water loading and acute hyponatremia to the demise of this patient.

4.
Int J Mol Sci ; 21(4)2020 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-32102247

RESUMO

Tryptophan is an essential dietary amino acid that originates uremic toxins that contribute to end-stage kidney disease (ESKD) patient outcomes. We evaluated serum levels and removal during haemodialysis and haemodiafiltration of tryptophan and tryptophan-derived uremic toxins, indoxyl sulfate (IS) and indole acetic acid (IAA), in ESKD patients in different dialysis treatment settings. This prospective multicentre study in four European dialysis centres enrolled 78 patients with ESKD. Blood and spent dialysate samples obtained during dialysis were analysed with high-performance liquid chromatography to assess uremic solutes, their reduction ratio (RR) and total removed solute (TRS). Mean free serum tryptophan and IS concentrations increased, and concentration of IAA decreased over pre-dialysis levels (67%, 49%, -0.8%, respectively) during the first hour of dialysis. While mean serum total urea, IS and IAA concentrations decreased during dialysis (-72%, -39%, -43%, respectively), serum tryptophan levels increased, resulting in negative RR (-8%) towards the end of the dialysis session (p < 0.001), despite remarkable Trp losses in dialysate. RR and TRS values based on serum (total, free) and dialysate solute concentrations were lower for conventional low-flux dialysis (p < 0.001). High-efficiency haemodiafiltration resulted in 80% higher Trp losses than conventional low-flux dialysis, despite similar neutral Trp RR values. In conclusion, serum Trp concentrations and RR behave differently from uremic solutes IS, IAA and urea and Trp RR did not reflect dialysis Trp losses. Conventional low-flux dialysis may not adequately clear Trp-related uremic toxins while high efficiency haemodiafiltration increased Trp losses.


Assuntos
Hemodiafiltração/métodos , Falência Renal Crônica/terapia , Diálise Renal/métodos , Triptofano/sangue , Triptofano/toxicidade , Triptofano/urina , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Indicã/sangue , Indicã/urina , Ácidos Indolacéticos/sangue , Ácidos Indolacéticos/urina , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência Renal Crônica
5.
PLoS One ; 13(3): e0193288, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29529055

RESUMO

INTRODUCTION: Bisphenol A (BPA) is an ubiquitous environmental toxin that is also found in dialyzers. Online hemodiafiltration (OL-HDF) more efficiently clears high molecular weight molecules, and this may improve BPA clearance. However, the BPA contents of dialysis membranes may be a source of BPA loading during OL-HDF. METHODS: A prospective study assessed plasma BPA levels in OL-HDF patients using BPA-free (polynephron) or BPA-containing (polysulfone) dialyzers in a crossover design with two arms, after a run-in OL-HDF period of at least 6 months with the same membrane: 31 patients on polynephron at baseline were switched to polysulfone membranes for 3 months (polynephron-to-polysulfone) and 29 patients on polysulfone were switched to polynephron for 3 months (polysulfone-to-polynephron). RESULTS: After a run-in OL-HDF period of at least 6 months with the same membrane, baseline pre-dialysis BPA was lower in patients on polynephron (8.79±7.97 ng/ml) than in those on polysulfone (23.42±20.38 ng/mL, p<0.01), but still higher than in healthy controls (<2 ng/mL). After 3 months of polynephron-to-polysulfone switch, BPA was unchanged (8.98±7.88 to 11.14±15.98 ng/mL, ns) while it decreased on the polysulfone-to-polynephron group (23.42±20.38 to 11.41±12.38 ng/mL, p<0.01). CONCLUSION: OL-HDF for 3 months with BPA-free dialyzer membranes was associated to a significant decrease in predialysis BPA levels when compared to baseline BPA levels while on a BPA-containing membrane.


Assuntos
Compostos Benzidrílicos/sangue , Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Fenóis/sangue , Polímeros/química , Sulfonas/química , Estudos Cross-Over , Feminino , Humanos , Falência Renal Crônica/sangue , Masculino , Membranas Artificiais , Polímeros/efeitos adversos , Estudos Prospectivos , Diálise Renal/instrumentação , Sulfonas/efeitos adversos
6.
J Am Soc Nephrol ; 27(5): 1566-74, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26432902

RESUMO

Bisphenol A (BPA), a component of some dialysis membranes, accumulates in CKD. Observational studies have linked BPA exposure to kidney and cardiovascular injury in humans, and animal studies have described a causative link. Normal kidneys rapidly excrete BPA, but insufficient excretion may sensitize patients with CKD to adverse the effects of BPA. Using a crossover design, we studied the effect of dialysis with BPA-containing polysulfone or BPA-free polynephron dialyzers on BPA levels in 69 prevalent patients on hemodialysis: 28 patients started on polysulfone dialyzers and were switched to polynephron dialyzers; 41 patients started on polynephron dialyzers and were switched to polysulfone dialyzers. Results were grouped for analysis. Mean BPA levels increased after one hemodialysis session with polysulfone dialyzers but not with polynephron dialyzers. Chronic (3-month) use of polysulfone dialyzers did not significantly increase predialysis serum BPA levels, although a trend toward increase was detected (from 48.8±6.8 to 69.1±10.1 ng/ml). Chronic use of polynephron dialyzers reduced predialysis serum BPA (from 70.6±8.4 to 47.1±7.5 ng/ml, P<0.05). Intracellular BPA in PBMCs increased after chronic hemodialysis with polysulfone dialyzers (from 0.039±0.002 to 0.043±0.001 ng/10(6) cells, P<0.01), but decreased with polynephron dialyzers (from 0.045±0.001 to 0.036±0.001 ng/10(6) cells, P<0.01). Furthermore, chronic hemodialysis with polysulfone dialyzers increased oxidative stress in PBMCs and inflammatory marker concentrations in circulation. In vitro, polysulfone membranes released significantly more BPA into the culture medium and induced more cytokine production in cultured PBMCs than did polynephron membranes. In conclusion, dialyzer BPA content may contribute to BPA burden in patients on hemodialysis.


Assuntos
Compostos Benzidrílicos/sangue , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Membranas Artificiais , Fenóis/sangue , Diálise Renal , Idoso , Materiais Biocompatíveis , Estudos Cross-Over , Humanos , Polímeros , Estudos Prospectivos , Sulfonas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...